Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three OMRON Load sensor.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-VLC-L2ET11 AC100-240
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON Load sensor.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM OMRON Load sensor. Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: SPDT × 1.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Lineup includes a 17 mV instrument PDF datasheet. 5-mm slim, compact model.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supports phase loss detection wheen the motor is operating K3HB-VLC-L2ET11 AC100-240 PDF datasheet.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors mV instrument PDF datasheet. Setting range: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay mV instrument PDF datasheet.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weiight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-VLC-L2ET11 AC100-240 PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equippped with the sub pressure gauge for monitoring the operation trend K3HB-VLC-L2ET11 AC100-240 PDF datasheet.
External event input can be applied to a variety of measurement and identification