Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Input type: DC voltage input type.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with OMRON K3HB-VLC-L2BT11 AC100-240.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-VLC-L2BT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend OMRON K3HB-VLC-L2BT11 AC100-240.
External event input can be applied to a variety of measurement and identification situations.
DeviceType of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Relay contact: HH; PASS1c, H, L, LLL: each 1a mV instrument.
96 (W) * 48 (H * 95mm) depth OMRON K3HB-VLC-L2BT11 AC100-240.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution OMRON Load sensor.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeviceNetSupply voltage: 12 VDC.
Control output: Contact output, DPDT (time-limit DPDT,
or time-limit SPDT + instantaneous SPDT) Changed using a switch OMRON Load sensor.
Eight-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0 OMRON Load sensor.
Start signal control for the H3DK-M. Type: no instantaneous contact.
Terminal configurattion type: special terminal configuration K3HB-VLC-L2BT11 AC100-240.
Pin type: 8 pin.
Action mode / reset mode: time limit action / auto reset.
Output mode: contact output.
Installation method: embedded installation / front mounting.
1 units can be in 0.55 seconds to 120 seconds, select the 4 time range mV instrument.
Achieved UL, CSA, NK, LR certification, in compliance with EN61812-1.
Conform to the CE mark, CCC.