Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 OMRON K3HB-XAA-L2AT11 AC100-240
K3HB-XAA-L2AT11 AC100-240
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT) OMRON K3HB-XAA-L2AT11 AC100-240.
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry. Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 3 transistor outputs (NPN open collector);
Data transmission output, RS-485.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D) OMRON K3HB-XAA-L2AT11 AC100-240.
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Project: Japanese specification model OMRON Voltage and current panel meter.
Installation method: surface /DIN rail installation (agreement) longitudinal.
All day control operation is simple
Can be carried out on the choice of a few weeks of action OMRON Voltage and current panel meter. (but only 1 of the week moves and all week specific dates can be set)
ON/OFF time setting has 24 steps.
Consistent with CE markers. Through the UL, CSA standard certification.
Rest day function can be easily carried out on holidays, such as the setting of a sudden break OMRON Voltage and current panel meter.
Test mode function can easily connfirm the program K3HB-XAA-L2AT11 AC100-240.
Can also be used to deal with a sudden change in the way of a semi automatic work.
The pulse action can cope with daylight saving time.
All models are equipped with finger protection function.
Produuct series contains embedded installation, surface mount, the size of the agreement and other ways OMRON K3HB-XAA-L2AT11 AC100-240.
The same setting can be done with the timer action.