LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> K3HB-XAA-FLK3AT11 AC100-240
OMRON K3HB-XAA-FLK3AT11 AC100-240 PDF catalog K3HB-XAA-FLK3AT11 AC100-240 datasheet PDF datasheet
Product model: K3HB-XAA-FLK3AT11 AC100-240
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load) K3HB-XAA-FLK3AT11 AC100-240 PDF datasheet.
Output relay can be switched between normally open and normally closed K3HB-XAA-FLK3AT11 AC100-240
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Type of input: AC voltage input.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a K3HB-XAA-FLK3AT11 AC100-240 PDF datasheet.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-XAA-FLK3AT11 AC100-240 PDF datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemType: Medium-sensitivity models.
Sensed current: 500 mA/1,000 mA(switchable).
Type: High-speed models.
Operating time: Less than 0.1 s.
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages.
Manual reseetting and automatically resetting supported by one Relay K3HB-XAA-FLK3AT11 AC100-240 PDF catalog.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-XAA-FLK3AT11 AC100-240 PDF catalog.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC100-240
OMRON Time interval table K3HB-PNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PPB-L1AT11 AC100-240
OMRON Time interval table K3HB-PPB-L1AT11 AC100-240
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PNB-AT11 AC100-240
OMRON Time interval table K3HB-PNB-AT11 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PPB-AT11 AC100-240
OMRON Time interval table K3HB-PPB-AT11 AC100-240
Input type: PNP input type. Event input