Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
an alarm signal.
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
work with both single-phase and three-phase heaters.
alarms due to variations in the supply voltage.
Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
AC 200, 220, 230, 240, AC 115, 127, 133, 138.
Ideal for 3-phase voltage asymmetry.
monitoring for industrial facilities and equipment.
Monitor voltage asymmetry, phase sequence, and phase loss,
for three-phase 3-wire or 4-wire power supplies with just one Unit OMRON K2CU-F10A-DGS.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply
K2CU-F10A-DGS
One SPDT output relay, 6 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Pole number: 10 * 2.
Pole pole number: 0.
Minimum packing unit: 63.
Printed board connector core, MIL specification standard OMRON K2CU-F10A-DGS.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved OMRON K2CU-F10A-DGS.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products OMRON Heater Element Burnout Detector. Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: P5 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz OMRON Heater Element Burnout Detector.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1C, 1A (voltage output contact);
AC 110V 7.5A cos (AC 250V maximum diameter =0.4 825VA),
5000 times 24V 5A L/R=7ms DC (max 125V 25W time DC) 5000 times OMRON Heater Element Burnout Detector.
Relay control output for circuit breaker switching.
Quality: about 0.5kg.
External: Mount Searl N1.5.
High voltage grounding relay AGF type, anti wave interference,
Arc grounding, short circuit capability, high relliability K2CU-F10A-DGS.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of thee specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate OMRON K2CU-F10A-DGS.
In all the models set up alarm terminal.