K2CU-F40A-D PDF datasheet OMRON K2CU-F40A-D datasheet PDF catalog
Product model: K2CU-F40A-D
Name: Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V OMRON K2CU-F40A-D PDF catalog.
Digital rotating pulse meter with high speed measurement for 50kHz K2CU-F40A-D
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Can rotate the encoder and a variety of ON/OFF pulse signal, up to 50kHzInput type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA OMRON K2CU-F40A-D PDF catalog.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time OMRON K2CU-F40A-D PDF catalog.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 3Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K2CU-F40A-D PDF datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CU-F40A-D PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Heater Element Burnout Detector
K2CU-F20A-D
OMRON Heater Element Burnout Detector K2CU-F20A-D
Control supply voltage: 110 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F20A-CGS
OMRON Heater Element Burnout Detector K2CU-F20A-CGS
Control supply voltage: 100 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F20A-FGS
OMRON Heater Element Burnout Detector K2CU-F20A-FGS
Control supply voltage: 220 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F40A-C
OMRON Heater Element Burnout Detector K2CU-F40A-C
Control supply voltage: 100 VAC With vo