Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
an alarm signal.
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
work with both single-phase and three-phase heaters.
alarms due to variations in the supply voltage.
Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
AC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort OMRON K2CU-F20A-FGS.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
K2CU-F20A-FGS
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified OMRON K2CU-F20A-FGS.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 50 W.
Output voltage: 5 V.
Output current: 10 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) OMRON K2CU-F20A-FGS.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage OMRON Heater Element Burnout Detector.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply OMRON Heater Element Burnout Detector. ).Power ratings: 960 W.
Input voltage: 3-phase, 380 to 480 VAC; 2-phase, 380 to 480 VAC.
Output Voltage: 24 V; 24 V.
Output current: 40 A; 32A OMRON Heater Element Burnout Detector.
Boost Current: 48 A; --.
Worldwide 3-phase Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Wide input range for worldwide applications:
380 to 480 VAC (320 to 576 VAC).
Possible for 2-phase input usage*:
380 to 480 VAC (340 to 576 VAC).
When using the 960 W at 2-phase input, the power rating is 768 W K2CU-F20A-FGS.
DC input can be available*:
450 to 600 VDC (450 to 810 VDC).
Excluding 960 W.
High efficiency 91% typ. at 480 W model.
Wide operation temperature range: –40 to 70°C.
Poweer Boost function at 120% OMRON K2CU-F20A-FGS.
Meets LR maritime standards.
EMS: Conforms to EN 61204-3.
EMI: EN61204-3 Class B.
RoHS Compliant.