OMRON K2CU-F40A-CGS PDF datasheet Heater Element Burnout Detector datasheet PDF catalog
Product model: K2CU-F40A-CGS
Name: Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: DC current input.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K2CU-F40A-CGS PDF catalog.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K2CU-F40A-CGS
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet typeSetting range: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC K2CU-F40A-CGS PDF catalog.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode K2CU-F40A-CGS PDF catalog.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Time specification: Instantaneous type OMRON Heater Element Burnout Detector PDF catalog.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC OMRON Heater Element Burnout Detector PDF catalog.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase OMRON Heater Element Burnout Detector PDF catalog.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation ttime,
is indicated from the start of operation K2CU-F40A-CGS PDF datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K2CU-F40A-CGS PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Heater Element Burnout Detector
K2CU-F40A-D
OMRON Heater Element Burnout Detector K2CU-F40A-D
Control supply voltage: 110 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F40A-C
OMRON Heater Element Burnout Detector K2CU-F40A-C
Control supply voltage: 100 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F80A-CGS
OMRON Heater Element Burnout Detector K2CU-F80A-CGS
Control supply voltage: 100 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F10A-D
OMRON Heater Element Burnout Detector K2CU-F10A-D
Control supply voltage: 110 VAC With vo