2 axes, open collector output type.
2 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types MITSUBISHI PLC Programming Guide Book
Q04UDHCPU
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps.) Input points: 16 points MITSUBISHI PLC Programming Guide Book.
Input voltage and current: 6mA DC5V.
Response time: 0/0.1/0.2/0.4/0.6/1ms.
16 point /1 a public side.
Positive / negative common.
18 point terminal station.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used MITSUBISHI PLC Programming Guide Book.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location Q04UDHCPU Programming Guide Book.
Q series module products include a variety of types of I/O, analog and positioning function module Q04UDHCPU Programming Guide Book.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Q04UDHCPU Programming Guide Book.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to tthe English letters, numbers, but also the use of special characters,
To further enhance the security of the password Q04UDHCPU Manual .
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorizeed access to unauthorized users MITSUBISHI PLC Programming Guide Book.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.