MITSUBISHI Q25HCPU PID Control Instructions Programming Manual
Product model: Q25HCPU
Name: PLC
Brand: MITSUBISHI
Sort: PID Control Instructions Programming Manual
File language: English
The bus can be equipped with Q series CPU module, interrupt module.
16 point.
DC24V.
Response time: 0.1/0.2/0.4/0.6/1ms.
16 point / common end.
Positive common end.
18 point terminal.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password Q25HCPU PID Control Instructions.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password Q25HCPU
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location Q25HCPU PID Control Instructions.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Q25HCPU PID Control Instructions.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.Output points: 8 points.
Output voltage and current: DC5~24A/ point; 8A/ common terminal.
OFF leakage current: 0.1mA.
Response time: 10ms.
Leaky type and source sharing.
18 point terminal station.
With the surge absorber.
All points of independence.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceeiver time between the CPU module Q25HCPU Programming Manual.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily diisplayed Q25HCPU Programming Manual.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Related products
MITSUBISHI
General purpose CPU
Q00UJCPU
MITSUBISHI General purpose CPU Q00UJCPU
Input / output points: 256 points. Nume
MITSUBISHI
CPU unit
A2NCPU
MITSUBISHI CPU unit A2NCPU
Input and output points: 512 points. Inp
MITSUBISHI
With Ethernet CPU
Q13UDEHCPU
MITSUBISHI With Ethernet CPU Q13UDEHCPU
Input / output points: 4096 points. Num