LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q00JCPU-S8-SET
Q00JCPU-S8-SET Programming Manual MITSUBISHI Q00JCPU-S8-SET Structured Text Manual
Product model: Q00JCPU-S8-SET
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
"2CH RS-232.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of programmable controllers using programming tools.
QJ71C24N (-R2) with the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a public telephone line MITSUBISHI Q00JCPU-S8-SET Manual Q00JCPU-S8-SET
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on MITSUBISHI Q00JCPU-S8-SET Manual .
Can achieve the highest speed of 230.4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications.
Can use MC protocol, through the external devices (PC, monitors, etc.) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the programmable controller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices MITSUBISHI Q00JCPU-S8-SET Manual . "FL-net (OPCN-2) Ver.1.00 interface.
10BASE5 use.Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Input: 4 channels.
Input: DC-10~10V, DC0~20mA.
Output (resolution): 0~4000, -4000~4000, 0~12000, 0~16000, -16000~16000.
Conversion speed: 500 s/1 channel.
18 point terminal.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reeduced due to the need for an external isolation amplifier Q00JCPU-S8-SET Programming Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module. Q00JCPU-S8-SET Programming Manual.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
Related products
MITSUBISHI
Small points with substrate CPU
Q00UJCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00UJCPU-S8-SET
Upgrade payments. Input / output points:
MITSUBISHI
Small points with substrate CPU
Q00JCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-S8-SET
Input / output points: 256 points. Progr
MITSUBISHI
CPU with base plate
Q00JCPU
MITSUBISHI CPU with base plate Q00JCPU
Program capacity: 8K step. Input / outpu
MITSUBISHI
CPU with base plate
Q00JCPU-S8
MITSUBISHI CPU with base plate Q00JCPU-S8
DC5V DC current consumption: 0.23A. Num