Max input / output points: 30 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 14 points.
Output type: Transistor (source).
Power consumption (W): 21.
Weight (kg):0.45.
Size (WxHxD) mm:100x90x75.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14 FX2N-64MR-D Manual
FX2N-64MR-D
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment FX2N-64MR-D Manual. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 5.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FX2N-64MR-D Manual.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical MITSUBISHI FX2N-64MR-D PROGRAMMING MANUAL II.
The inverter drive can be smoothly start (start time longer) MITSUBISHI FX2N-64MR-D PROGRAMMING MANUAL II.
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. Max input / output points: 10 points MITSUBISHI FX2N-64MR-D PROGRAMMING MANUAL II.
Supply voltage: 100 - 240VAC.
Input points: 6 points.
Output points: 4 points.
Output type: Transistor (source).
Power consumption (W): 6.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no bbattery, easy to maintain FX2N-64MR-D .
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BBD board to extend a small amount of I/O FX2N-64MR-D Manual.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.