Control power supply voltage: 24 VDC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
able) from 4 mV to 300 V.
DC circuits using shunt (SDV-FL).
rent using current converter.
Available in 7 supply voltage configurations.
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
verse current detection.
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Power rating: 35 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 5 V VDC.
Output current: 7 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation OMRON SDV-FH2.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage
SDV-FH2
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications OMRON SDV-FH2.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.5 .
Cable sheath material: PUR.
Cable color: Green OMRON SDV-FH2.
Cable length: 0.5 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Terminals: Push-In Plus terminal blocks.
Type: Input *1.
Points: 16.
Internal I/O circuit common: NPN (– common) OMRON Voltage Sensor.
Rated voltage: 24 VDC.
I/O Relay Terminals with 16 Points and,
Push-In Plus terminal blocks to,
Downsize Control Panels and Save Labor.
I/O Relay Terminals with 16 points to mount G2RV Slim I/O Relays OMRON Voltage Sensor.
Push-In Plus terminal blocks are used to save wiring work in,
comparison with traditional screw terminals. (Wiring time is,
reduced by 60%* in comparison with traditional screw terminals.).
Work is reduced ever further with one-step cable connection to the PLC OMRON Voltage Sensor.
Diode provided for coil surge absorption.
Operation indicators for immediate recognition of I/O signal status.
Accepts G3RV Slim I/O SSRs.
DIN Track or screw mounting. Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrrents SDV-FH2.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SSPDT output contacts, 5 A at 250 VAC (resistive load) OMRON SDV-FH2.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.