LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> SDV-DH2
OMRON SDV-DH2 datasheet PDF datasheet
Product model: SDV-DH2
Name: Voltage Sensor
Brand: OMRON
Sort: PDF datasheet
File language: English
Power ratings: 60 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 2.5 A.
Alarm output *2: --.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication SDV-DH2 datasheet.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that SDV-DH2
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) SDV-DH2 datasheet.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Appearance: insert type.
Control supply voltage: AC200/220/240V.
Action elements: overload detection.
Action characteristic: anti time limit action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection SDV-DH2 datasheet.
A variety of models, such as anti time limit characteristics, lock time, instantaneous action, etc., are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT or the relay part is not needed, and the use is simple.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple. Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: --.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output stanndards SDV-DH2 PDF datasheet.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) SDV-DH2 PDF datasheet.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
Related products
OMRON
Voltage Sensor
SDV-FH2T
OMRON Voltage Sensor SDV-FH2T
Control power supply voltage: 24 VDC. I
OMRON
Voltage Sensor
SDV-FH2
OMRON Voltage Sensor SDV-FH2
Control power supply voltage: 24 VDC. I
OMRON
Voltage Sensor
SDV-FH7T
OMRON Voltage Sensor SDV-FH7T
Control power supply voltage: 200/220 VA
OMRON
Voltage Sensor
SDV-DM2
OMRON Voltage Sensor SDV-DM2
Control power supply voltage: 24 VDC. I