Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Output: DPDT.
Supply voltage: 110 VAC (50/60 Hz); 220 VAC (50/60 Hz).
Timer: S-series; M-series.
Long power OFF-delay times;
S-series: up to 12 seconds,
M-series: up to 12 minutes.
Setting rings (order separately) to enable consistent,
settings and to limit the setting range.
Panel Covers (order separately) to enable various panel designs OMRON K3HB-XVA-T11 AC100-240.
Approved by UL, CSA, CE and CCC
K3HB-XVA-T11 AC100-240 Type of input: AC voltage input.
Output type: DeviceNet; -; DeviceNet.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table OMRON K3HB-XVA-T11 AC100-240.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
(depthInput type: DC voltage input type OMRON K3HB-XVA-T11 AC100-240.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with OMRON Voltage and current panel meter.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table OMRON Voltage and current panel meter.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeOutputs: Time-limit contact and instantaneous contact OMRON Voltage and current panel meter.
Supply voltage: 100 to 120 VAC; 200 to 240 VAC.
8-pin models.
DIN 48 × 48-mm Star-delta Timer.
A wide star-time range (up to 120 seconds) and star-delta.
transfer time range (up to 1 seconds). Operating method: Reversible (selectable with rotary DIP switch) between,
0 and the set value; Incrementing/decrementing A/D (command inputs);
Incrementing/decrementing B/E (individual inputs);
Incrementing/decrementing C/F (phase difference inputs).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: No . K3HB-XVA-T11 AC100-240.
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rrewiring OMRON K3HB-XVA-T11 AC100-240.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking.