LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> K3HB-VLC-EBCD1 AC100-240
K3HB-VLC-EBCD1 AC100-240 PDF catalog OMRON K3HB-VLC-EBCD1 AC100-240 datasheet PDF datasheet
Product model: K3HB-VLC-EBCD1 AC100-240
Name: Load sensor, mV instrument
Brand: OMRON
Sort: PDF datasheet
File language: English
Static type reverse electric relay K2FW type.
Ensure high accuracy digital UFR/OFR.
Constitute by the crystal oscillator plus digital IC,
Can achieve high accuracy of frequency detection (adjustment, detection accuracy of less than 0.1HZ).
50-60HZ share, can be adjusted arbitrarily in the range of 45-65HZ through the surface of the dial switch plate OMRON K3HB-VLC-EBCD1 AC100-240 PDF datasheet.
Because of the high speed detection, the low frequency relay can detect the system accident before the under voltage relay K3HB-VLC-EBCD1 AC100-240 Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3 OMRON K3HB-VLC-EBCD1 AC100-240 PDF datasheet. 5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not OMRON K3HB-VLC-EBCD1 AC100-240 PDF datasheet.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coordination between OCR andd MCCB is simple K3HB-VLC-EBCD1 AC100-240 PDF catalog.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident K3HB-VLC-EBCD1 AC100-240 PDF catalog.
Reduce the consumption of VA, reduce the burden of converter.
Related products
OMRON
Time interval table
K3HB-PPB-ABCD1 AC100-240
OMRON Time interval table K3HB-PPB-ABCD1 AC100-240
Input type: PNP input type. Event input
OMRON
Load sensor, mV instrument
K3HB-VLC-EBCD1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-EBCD1 AC100-240
Category: external supply 100mA DC5V typ