LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
CRT1-VAD04ML OMRON CRT1-VAD04ML
Brand: OMRON
Name: Analog I/O Slave Units
Model: CRT1-VAD04ML
Name: MIL Connector Type.
Specifications: Analog inputs; 4 inputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

I/O classification: Analog input.
I/O points: 4.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
I/O specification: 4 to 20 mA, 0 to 20 mA, 0 to 5 V,
1 to 5 V, 0 to 10 V, -10 to 10 V.
Analog Input/Output Units Compatible with MULTIPLE I/O TERMINAL.
Input block incorporates connectors that can be easily,
mounted or dismounted OMRON CRT1-VAD04ML. (GT1-AD08MX, GT1-DA04MX)
8 or 4 inputs CRT1-VAD04ML
4 outputs.
High resolution of 1/6,000.
High conversion speed of 8 ms/8 points or 4 ms/4 points.
DIN track mounting.
Connector model Terminal Block Model. I/O classification: SSR.
I/O points: 8.
I/O connections: M3 terminal block.
Power supply voltage: 24 VDC.
I/O specification: --.
Relay Output Unit Compatible with MULTIPLE I/O TERMINAL OMRON CRT1-VAD04ML.
8- and 16-point relay output models are available.
Equipped with 8-point SSRs.
DIN track mounting. Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced OMRON CRT1-VAD04ML.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON Analog I/O Slave Units. Input/Output: Outputs OMRON Analog I/O Slave Units.
Internal I/O circuit common: PNP (+ common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation OMRON Analog I/O Slave Units. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
cconstruction (IP67) enables direct on-site,
mounting CRT1-VAD04ML.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (88-point models) OMRON CRT1-VAD04ML.
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.


...More relevant models >>>>
Last one: CRT1-TS04P
next one: CRT1-VDA02ML