C500-OC I/O Unit Transistor Output 16 pts C500-OC223-E(3G2A5-OC223-E).
AC250/DC24V 2A.C500-DA/3G2A5-DA Special I/O Unit Analog Output C500-DA004(3G2A5-DA004).
Output: 2 pts.
Specification: -10~+10V.Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Unit with MECHATROLINK-II interface CRT1-VID16ML datasheet.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications
CRT1-VID16ML
Direct operation by ladder programming.
Control mode: Position control,
speed control or torque control;
No. of axes: 2 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management CRT1-VID16ML datasheet.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks CRT1-VID16ML datasheet.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Specifications: With clock (see below).Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 inputs, 32 outputs;
Input voltage,Input current, 24VDC, 4.1mA,
12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0.14A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.
Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Units with EtherCAT interface.
Specifications: Control output interface,
Control commands executed by,
EtherCAT communications.
Positioning functions: Memory operation,
Direct operation by ladder programming;
No. of axes: 8 axes.
No. of unit numbers allocated: 11 CRT1-VID16ML PDF datasheet.
Current consumption : 5V, 0.46A; 24V,--.
Standards: UC1, CE.
Preeminent control performance and,
easy operation feature of EtherCAT,
improve the production efficiency.
The EtherCAT communications with,
100Mbps bbaud rate enables fast,
and accurate position control CRT1-VID16ML PDF datasheet.
A wide range of position control,
functions are available with,
this position control unit.