LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
A1SJ71PT32-S3 The main PLC in the network can control 64 remote I/O modules MITSUBISHI A1SJ71PT32-S3 Master control module
Brand: MITSUBISHI
Name: Master control module
Model: A1SJ71PT32-S3
Cable type: cable or twisted pair.
A1SJ71PT32-S3 and A1SJ71PT32-S3 are the main control module of MELSECNET/MINI-S3,
The main PLC in the network can control 64 remote I/O modules.
The main control module carries on the high speed data communication to the remote module on the connection network.
Each PLCCPU can use a number of main control modules,
But up to no more than the maximum allowed by the main I/O CPU points.
A1SJ71PT32-S3 can be used in the cable system can also be used in twisted pair cable system;
A1SJ71T32-S3 can only be used in twisted pair cable network.
The popularization and application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment.
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram. Its characteristics are basically consistent with the ladder diagram language.

Output type: transistor source.
Output points: 32 points.
Load voltage: DC12/24.
Load current: 0.1A.
Connection: type D connector.
Common public end points: 32.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC MITSUBISHI A1SJ71PT32-S3.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A1SJ71PT32-S3
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic MITSUBISHI A1SJ71PT32-S3.
And the control principle is decentralized, centralized and hybrid control three. SI/QSI/H-PCF/ wide H-PCF optical cable dual layer remote I/O network (remote I/O station)
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI A1SJ71PT32-S3.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three MITSUBISHI Master control module.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of MITSUBISHI Master control module.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the externall output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle sccan mode of PLC and the way of PLC to refresh the I/O and so on MITSUBISHI Master control module MITSUBISHI A1SJ71PT32-S3 A1SJ71PT32-S3.
This phenomenon is called the I/O delay time effect.


...More relevant models >>>>
Last one: A1SJ72T25B
next one: A1SJ71T32-S3