Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. "Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Program capacity: 20K step.
Control mode: stored procedure repeated operation MITSUBISHI GT15-C50VG.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz
GT15-C50VG
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators MITSUBISHI GT15-C50VG.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement MITSUBISHI GT15-C50VG.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "Max input / output points: 48 points.
Power supply voltage: 24VDC.
Input points: 24 points.
Output points: 24 points.
Output type: Transistor (source).
Power consumption: 30W.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Paassword protecttion, using a eight digit password to protect your program GT15-C50VG.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off tthe continuous scan time GT15-C50VG.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
GT15-C50VG Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GT15-C50VG&select=5