"Axis of control: 32.
Program language: motion SFC, special instruction.
Servo program capacity: 32K.
Location points: 6400 (indirect).
Servo amplifier connection mode: SSCNET III /H (2 system).
Suitable for a variety of purposes.
Winding material, such as film, can be put down by fixed tension.
Speed control using advanced synchronous control,
To keep the entire production line in sync MITSUBISHI .
Workpiece position can be obtained directly from the visual system,
High speed motion control to change the position of the target in the process of operation, reduce the positioning time
FA-TB16XYPN3
Advanced synchronous control and speed / torque control,
High speed and high precision synchronous control of various printing modules MITSUBISHI .
Motion SFC program.
Motion CPU module through "Function Chart Sequential", in the form of flow chart description of motion control program.
The program can be used to describe the motion CPU module of the SFC module, which is suitable for event processing,
Using motion CPU module to control a series of movements of equipment, improve the response of the event MITSUBISHI . "Input and output points: 2048 points .
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:1.0.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage cappacity: it is a measure of hhow much the user application can store the number of indicators MITSUBISHI FA-TB16XYPN3.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words MITSUBISHI FA-TB16XYPN3. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
FA-TB16XYPN3 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FA-TB16XYPN3&select=5