FA-TB161ACC2 MITSUBISHI FA-TB161ACC2
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB161ACC2
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

Can be used as a screw relay terminal. Negative common end useConvert connectors to e-CON.Differential output.
Axis of control: 1.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period MITSUBISHI FA-TB161ACC2 FA-TB161ACC2
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time MITSUBISHI FA-TB161ACC2.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action. Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V MITSUBISHI FA-TB161ACC2.
Input current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value MITSUBISHI Conversion module.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup MITSUBISHI Conversion module.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range MITSUBISHI Conversion module.
For the detection of the lower limit or the uppper limit of the input signal abnormality, or when the detection of the broken line is performed FA-TB161ACC2.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the brooken line can be easily detected MITSUBISHI FA-TB161ACC2. Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module.