DC input points: 2 points.
Input voltage and current: 7mA, DC24V.
Input response time: 10ms.
2 point /1 a public side.
Positive / negative sharing.
Output points: 2 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 4A/1 common end.
Output response time: 2ms.
2 point /1 a public side.
Output form: relay MITSUBISHI HG-JR15K1.
16 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered
HG-JR15K1
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system MITSUBISHI HG-JR15K1.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI HG-JR15K1.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Analog input channel number: 8CH.
Cold end compensation accuracy: plus or minus 1.
Available thermocouple: B, R, S, K, E, J, T, N.
Available temperature resistance: -.
Resolution 1:B, R, S, N:0.3
Resolution 2:K, E, J, T:0.1
Conversion speed: 30ms/CH.
Insulation between channels: isolation transformer insulation.
Disconnection detection: there.
External wiring connection mode: 40 pin connector.
output
The temperature measurement value (16 bit''signed binary): 2700 ~ 18200.
Zoom value (16 bit with symbol binary).
High speed data sampling is not affected by the scan time.
The analog input module has the function of recording, which can be used to collect the analog quantity input data in the industrial application.
Can continuously collect data in a set period, each channel can store up to 10000 points of the recorded data.
In addition, the state of the state of any time and data in the program can be changed as a trigger,
To stop collecting data. The analog quantity input data can be stored and maintained beefore and after the trigger state through the function,
Easy to determine the occurrence of the phenomenon and the collection of test data HG-JR15K1. Such as motor testing equipment used in this function.
Control instructions from a programmablee ccontroller to a transducer and a power meter transmission test mode,
At the same time, the test data of the test motor is collected at the same time HG-JR15K1.