Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input OMRON B3S-1000.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485
B3S-1000
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O OMRON B3S-1000. Suitable for more applications.
E5AC white LCDPV display height is about 25mm .
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON B3S-1000.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Classification: Input (bifurcated contact), SPST-NO.
Rated voltage: 12 VDC, 24 VDC, 100/110 VAC, 200/220 VAC.
Slim-styled I/O Relay Saves Space in Panel.
SPST-NO, SPST-NC, and SPDT contact forms available for,
output (SPST-NO only for input).
Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
All Output Relays provide a long endurance (1,000,000,
operations at 5 A), while all Input Relays provide microswitching,
power (100 μA at 1 V).
Approved by UL and CSA standards. Type: Welding / wire type, with left column.
Drive rod: needle shaped button type.
Terminal specifications: with wire, the left side.
Contact speccifications: 1a B3S-1000.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used fforr easy long stroke specifications (OT reference value: 1 B3S-1000. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.
B3S-1000 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=B3S-1000&select=5