Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 100 W.
Output voltage: 5 V.
Output current: 20 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).
Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/M12 Right-angle).
Cable length: 1 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A OMRON S8JX-G10005D.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities
S8JX-G10005D
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements OMRON S8JX-G10005D.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Detected voltage: AC.
Compact, Economical Plug-in Type Voltage.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication OMRON S8JX-G10005D.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal.
Wide voltage setting range with fine setting capability OMRON Switch Mode Power Supply. Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min OMRON Switch Mode Power Supply.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2.1 m3/min.
Maximum static pressure: 50 Hz, 47 Pa; 60 Hz, 44 Pa.
Noise: 50 Hz, 45 dB; 60 Hz, 46 dB.
Weight: Approx. 2220 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting OMRON Switch Mode Power Supply.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work S8JX-G10005D.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and VVent Attachment OMRON S8JX-G10005D.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.