Optical system: diffuse type.
Detection distance: 50 positive and negative 5mm.
Beam shape: linear beam.
Beam diameter: 900mm * 60 M.
Resolution: 0.8 M.
Cable length: 0.5m. Type: square.
Screen mode: no segmentation.
Output: SPDT.
Power supply voltage: DC12V.
Contact type: standard load (AC250V, 3A; DC30V, 3A) OMRON B3F-5150.
Operation: alternating action (self retaining).
Operation Department color: White (using yellow and green LED)
B3F-5150
In the touch and the ability to protect than OMRON''s previous models have improved.
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing.
LED has five colors (red, yellow, green, white, and blue) OMRON B3F-5150.
Built in basic switch improves touch .
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action) OMRON B3F-5150.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards .
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the statuss of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV B3F-5150.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs B3F-5150.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
B3F-5150 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=B3F-5150&select=5