2 channel.
Input: DC4~20mA (connecting two wire transmitter); DC0~20mA.
Output (resolution): 0~4000. 0~12000.
Conversion speed: 10ms/ channel.
40 pin connector.
Isolation between channels.
Power supply to a two wire transmitter.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark MITSUBISHI Basic type CPU PDF datasheet
Q00CPU
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier MITSUBISHI Basic type CPU PDF datasheet.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.PCI bus.
Support Japanese, English OS MITSUBISHI Basic type CPU PDF datasheet.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
With external power supply function.
Province distribution network module in cabinet and device Q00CPU PDF datasheet.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2 Q00CPU PDF datasheet. 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
MELSECNET/H network module capable of composing large scale flexible network system Q00CPU PDF datasheet.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the lengtth of the total cable length, strong anti-interference Q00CPU PDF catalog.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system MITSUBISHI Basic type CPU PDF datasheet. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.