Setting range: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-XAD-AT11 AC100-240 PDF catalog.
Output relay can be switched between normally open and normally closed
K3HB-XAD-AT11 AC100-240
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control K3HB-XAD-AT11 AC100-240 PDF catalog.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output K3HB-XAD-AT11 AC100-240 PDF catalog.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads OMRON Voltage and current panel meter PDF catalog OMRON Voltage and current panel meter PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL) OMRON Voltage and current panel meter PDF catalog.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speeed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XAD-AT11 AC100-240 PDF datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations K3HB-XAD-AT11 AC100-240 PDF catalog.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.