Contact form: DPDT.
Classification: Arc barrier equipped model.
Plug-in terminals.
Magnetic Latching Version of G2A Ideal for.
Sequence Control.
Double-winding latch system with continuous rating.
Terminals pulled from the respective junctions between the,
built-in diodes and set and reset coils allow the built-in diodes to,
be externally connected for coil surge absorption G3PE-535B-3H DC12-24 PDF datasheet
G3PE-535B-3H DC12-24
Excellent vibration/shock resistance with minimal secular,
decrease in latching power.
Easy monitoring of ON/OFF operation due to the built-in,
operation indicator mechanism.
Same outline dimensions as the standard models of G2A. Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: AC load G3PE-535B-3H DC12-24 PDF datasheet.
Zero cross function: Yes.
Rated input voltage: AC/DC 48V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals G3PE-535B-3H DC12-24 PDF datasheet.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures G3PE-535B-3H DC12-24 PDF catalog.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G3PE-535B-3H DC12-24 PDF catalog.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.