Catalog Download >> E3JK-RR11 2M
E3JK-RR11 2M PDF catalog OMRON E3JK-RR11 2M datasheet PDF datasheet
Product model: E3JK-RR11 2M
Name: Built-in Power Supply Photoelectric Sensor
Brand: OMRON
Sort: PDF datasheet
File language: English
Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON E3JK-RR11 2M PDF datasheet E3JK-RR11 2M
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating OMRON E3JK-RR11 2M PDF datasheet.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 OMRON E3JK-RR11 2M PDF datasheet. 5mm). Terminal type: Enclosed-terminal Models.
Protective tubing length L: 35cm.
Protective tubing diameter D (mm): 8 dia.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 15cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Seensors E3JK-RR11 2M PDF catalog.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3JK-RR11 2M PDF catalog.