Appearance: Unshielded, M18.
Sensing distance: 16 mm.
Model: NC.
Long-distance Proximity Sensor.
Long-distance detection at up to 30 mm enables secure mounting,
with reduced problems due to workpiece collisions.
No polarity for easy wiring with DC 2-wire models.
Cable protector provided as a standard feature E3JK-RR12 2M PDF datasheet. Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit
E3JK-RR12 2M
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-485 or RS-232C selectable.
From End Unit: Port A: RS-485 E3JK-RR12 2M PDF datasheet.
Input type: No input.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design E3JK-RR12 2M PDF datasheet.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type.
Polarity: there.
Shape: shield, M12.
Detection range: 3mm.
Action mode: NC. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the staate of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3JK-RR12 2M PDF catalog.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E3JK-RR12 2M PDF catalog.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.