Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E3T-ST32-ECON Manual
E3T-ST32-ECON
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E3T-ST32-ECON Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E3T-ST32-ECON Manual. , can be a key operation. Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 4 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP OMRON E3T-ST32-ECON INSTRUCTION sheet.
Operation mode NC.
A new generation in global applications. Control output: voltage output (SSR driver).
Auxiliary output: 2 points OMRON E3T-ST32-ECON INSTRUCTION sheet.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: 1 points.
Communication: -.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON E3T-ST32-ECON INSTRUCTION sheet.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication addapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E3T-ST32-ECON .
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E3T-ST32-ECON Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).