Size: M12 (Brass); Double; Unshielded.
Sensing distance: 30 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Sensor type: Diffuse-reflective.
Sensing distance: 100 mm.
Connection method: M12 connector E3T-ST32-M1TJ INSTRUCTION sheet.
Model: NPN output.
A new generation in sensing performance
E3T-ST32-M1TJ
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. Model: Shielded, M12 E3T-ST32-M1TJ INSTRUCTION sheet.
Sensing distance: 2 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NO.
Proximity Sensor with Resin Case,
with Superb Water Resistance.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer E3T-ST32-M1TJ INSTRUCTION sheet.
Auxiliary outputs: None.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check thee state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3T-ST32-M1TJ Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E3T-ST32-M1TJ Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.