5 slots.
Requires 1 power modules.
Used to install the old section of the large A series PLC module.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI Q173CPU Manual.
So, sometimes also known as the order control
Q173CPU
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read MITSUBISHI Q173CPU Manual.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three MITSUBISHI Q173CPU Manual.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.Control axis: up to 16 axes.
Interpolation function: linear interpolation (maximum 4 axis), arc interpolation (2 axis), spiral interpolation (3 axis).
PLC capacity: 60K step.
Can control the maximum 16 axis servo amplifier.
With the position control, speed control, torque control, advanced synchronous control and other rich control methods.
The incremental synchronous encoder I/F and the symbol detection signal I/F are integrated in the 1 modules.
Capacity expansion can be expanded to PLC capacity 60K step (using Q170MSCPU-S1), the 7 layer of the substrate Q173CPU Programming Manual.
Combined with the servo amplifier to achieve safe torque off (STO).
Connect directly to the visual system produced by Ethernet through the COGNEX connection.
Connecction SSCNET III /H main module LJ72MS15 can use the MELSEC-L series of input Q173CPU Programming Manual.
Output module, analog input and output module, high speed counter module.