LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q06HCPU
Q06HCPU Manual MITSUBISHI CPU Q06HCPU MELSAP-L Programming Manual
Product model: Q06HCPU
Name: CPU
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
GI-50/125 optical cable.
Double ring.
PLC to PLC network (control station / common station) / remote I/O network / (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station MITSUBISHI CPU Programming Manual Q06HCPU
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network MITSUBISHI CPU Programming Manual.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Positioning: 3 axis, built-in counter function, open collector output type.
Control unit: pulse.
Number of location data: 1/ axis.
Maximum output pulse: 100Kpps.
Counter: 3 channels.
100Kpps.
Counter input signal: DV5~24V MITSUBISHI CPU Programming Manual.
40 pin connector.
Positioning control using encoder feedback, especially suitable for conveying system and processing machinery, etc..
In the 1 single module, the 3 axis positioning function and the 3 channel counter function are integrated Q06HCPU Programming Manual.
Positioning module, high-speed counter module combined as a whole,
Can effectively use the board slot and save space Q06HCPU Programming Manual. Storage card protection for universal Q series CPU.
Q3MEM-4MBS-SET/Q3MEM-8MBS-SET bundled products.Master station module supporting AnyWireASLINK system.
Connecting sensor and programmable controller.
Free configuration of sensors, control of 512 points of the input and output Q06HCPU Programming Manual.
The AnyWireASLINK transmission line (2 lines) can be used for communication to supply power for the sensor, and the sensor can also be conveniently added.
Can through the project software GXWorks2 batch management sensor shedding detection and from the station module settings, etc.,
Substantial savings in time and cost.Compact flash memory card.
Capacity: 512M bytes. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperatuure regulating module has the function of preventing overheating and preventing over cooling Q06HCPU Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode MITSUBISHI CPU Programming Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products