LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
R08PCPU Terminal module MITSUBISHI R08PCPU
Brand: MITSUBISHI
Name: CPU
Model: R08PCPU

Analog input channel number: 16CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 35ppm/.
Common
Conversion speed: 10ms.
Insulation between channels: isolation transformer insulation MITSUBISHI R08PCPU.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection: 40 pin connector two R08PCPU
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
Execute event driven program through alarm output
Strengthen the implementation of the interrupt function according to the alarm output flag, easy to carry out preventive maintenance MITSUBISHI R08PCPU.
The measured value and the change rate of the analog input signal exceed the upper and lower limits of the set,
Regardless of the procedure of the scan time, can be executed interrupt handling, quickly respond to abnormal conditions.
Analog input module for the external analog signal into the interface of the programmable controller MITSUBISHI R08PCPU.
Can choose the channel between the insulation, voltage input, current input, voltage / current mixed input, thermocouple input, temperature resistance (RTD) input for a variety of purposes, such as modules.
Filter high frequency interference MITSUBISHI Terminal module.
Analog input module has been equipped with a first order lag filter.
The analog input signal with high frequency interference component can be obtained by using the first order lag filter MITSUBISHI Terminal module.
Parameters can be set through the filter time constant, no program can be easy to use. Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 80K.
Increase the speed of a constant cycle interrupt program MITSUBISHI Terminal module.
Perform a minimum interval constant period interrupt program can be shortened to 50 s,
Programmable logic controller can read more high-speed signals.
In addition, the interrupt routine can be set priority, and the interrupt program with high priority is executed when the interrupt processing is interrupted.
Therefore, when the signal is read at a high speed, the program can read the signal from the constant cycle of the conventional input module +CPU module.
Data management using database functions.
Data and production performance data through computer management in the past can be managed by database management of a built-in programmable controller.
Database can be created in the SD memory card, and can use the special instructions to easily add, updaate, retrieve, delete data R08PCPU.
In addition, the database can be imported and exported through the Unicode text file format,
Share data with spreadsheet software. In particular, can be flexibly used in the production of many varietiess of food and beverage production line and other fields,
Effectively carry out the change of formula data and the management of production performance MITSUBISHI R08PCPU.


...More relevant models >>>>
Last one: R120ENCPU