LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> QS0J65BTS2-4T
PLC QS0J65BTS2-4T Manual MITSUBISHI QS0J65BTS2-4T Safety Guideline
Product model: QS0J65BTS2-4T
Name: PLC
Brand: MITSUBISHI
Sort: Safety Guideline
File language: English
Output points: 16 points.
Output voltage and current: 12~24V 0.1A/; DC point; 1.6A/ common.
OFF leakage current: 0.1mA;
Response time: 1ms; 1 point 16 public end; leaky type.
18 point terminal station
With heat protection.
With short circuit protection.
With the surge absorber.
Continue to go beyond, to climb the peak of Q series QS0J65BTS2-4T Manual.
Strengthen security function.
Can be set up to 32 characters of the file password QS0J65BTS2-4T
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights QS0J65BTS2-4T Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields QS0J65BTS2-4T Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings MITSUBISHI QS0J65BTS2-4T Safety Guideline MITSUBISHI QS0J65BTS2-4T Safety Guideline. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.3 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module MITSUBISHI QS0J65BTS2-4T Safety Guideline.
Base plate of AnS series PLC.
QA1S series PLC 3 slot main substrate.
AnS series of modules can be installed. "Maximum control axis: 4 axis.
Connection mode with servo amplifier: SSCNET III /H connection type.
The maximum distance between the drive units: 100m.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 4 set.
Even the long distance wiring can be flexible.
The use of fiber optic cable, with high speed, high performance, high reliability of the servo system controller network.
In addition to the traditional positioning control, but also to support speed / torque control and synchronous control.
Use simple movement module setup tool",
Can easily perform positioning settings, monitoring and debugging, etc..
In addition, the data can be collected and displayed synchronously with the motion controller.
SSCNET III /H connection to save the wiring, the maximum distance between the station up to 100m,
Absolute position system can be easily supported.
The upper limit limit switch, the lower limit switch and the near point block signal are input by the servo amplifier,
Thus ggreatly reducing wiring QS0J65BTS2-4T .
In addition to positioning control and speed control, but also to perform synchronization control, cam control, torque control, touch pressure control, etc..
Positioning module (QD75MH) of the project annd the sequence of the previous model is highly compatible with the old model,
The project can be easily applied to the simple motion module (QD77MS) QS0J65BTS2-4T Manual. "