MITSUBISHI QS0J65BTS2-8D Manual QS0J65BTS2-8D Safety Application Guide
Product model: QS0J65BTS2-8D
Name: PLC
Brand: MITSUBISHI
Sort: Safety Application Guide
File language: English
MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment QS0J65BTS2-8D Safety Application Guide.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device QS0J65BTS2-8D
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device with multiple MODBUS communication from the station equipment QS0J65BTS2-8D Safety Application Guide. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)Input: 4 channels.
Platinum resistance (Pt10; JPt100).
Conversion speed: 40ms/1.
Channel 18 point terminal.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100).
Shedding detection function QS0J65BTS2-8D Safety Application Guide.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the looss of the program and the parameters due to forgetting to replace the battery QS0J65BTS2-8D Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and otther planned downtime,
The data is lost due to battery depletion QS0J65BTS2-8D Manual.
The next time the power is turned on, the backup data will be automatically restored.