LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q00UJCPU-SET
PLC Q00UJCPU-SET Common Instructions Manual MITSUBISHI Q00UJCPU-SET Programming Manual
Product model: Q00UJCPU-SET
Name: PLC
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Controller network (control station / common station) / remote I/O network (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station Q00UJCPU-SET Manual Q00UJCPU-SET
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network Q00UJCPU-SET Manual.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Input: 8 channels.
Thermocouple。
Conversion speed: 320ms/8 channel.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance Q00UJCPU-SET Manual.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery MITSUBISHI Q00UJCPU-SET Programming Manual MITSUBISHI Q00UJCPU-SET Programming Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored MITSUBISHI Q00UJCPU-SET Programming Manual.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Thrrough regular backup, can be the latest parameters, procedures, etc Q00UJCPU-SET Common Instructions. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q00UJCPU-SET Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Related products
MITSUBISHI
Small points with substrate CPU
Q00JCPU-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-SET
Input / output points: 256 points. Progr
MITSUBISHI
Small points with substrate CPU
Q00UJCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00UJCPU-S8-SET
Upgrade payments. Input / output points:
MITSUBISHI
Safety CPU
R32SFCPU-SET
MITSUBISHI Safety CPU R32SFCPU-SET
Safety grade SIL: SIL 3 IEC 61508. P
MITSUBISHI
General purpose CPU
Q00UJCPU-S8
MITSUBISHI General purpose CPU Q00UJCPU-S8
8 modules can e installed. Input / outp