Output configuration: DC switching NPN (normally open or closed selectable).
Sensing method: Reflective; Convergent reflective (Zone setting).
Sensing distance: 20 to 70 cm Sensing zone.
Capable of Setting the Sensing Range.
Using an Ultrasonic Beam.
Ensures the stable detection of a variety of objects,
regardless of the color, transparency, or material E5AN-HTPRR203BF-FLK INSTRUCTION Manual
E5AN-HTPRR203BF-FLK
(metallic or non-metallic) of the objects.
Limits the ultrasonic beam width to 8°, thus,
detecting minute objects as small as 2 x 2 cm.
Detects objects smoothly while largely suppressing,
interference from background objects.
Sealed to resist dust and dirt and emits ultrasonic,
waves at a frequency of approximately 200 kHz,
thus providing high immunity from impact and,
environmental noise E5AN-HTPRR203BF-FLK INSTRUCTION Manual. Power supply voltage: AC/DC power supply selectable type.
Sensing method: Through-beam (Emitter + Receiver).
Sensing distance: 5 m.
Output configu ration: Relay.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models) E5AN-HTPRR203BF-FLK INSTRUCTION Manual.
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance OMRON E5AN-HTPRR203BF-FLK Manual.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC) OMRON E5AN-HTPRR203BF-FLK Manual.
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Sensor type: BGS (background suppression).
Sensing distance: 100 mm.
Connection method: pre-wired.
Model: PNP output.
A new generation in sensing performance OMRON E5AN-HTPRR203BF-FLK Manual.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process off setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5AN-HTPRR203BF-FLK .
Through the infrared port can be carried out from the frront of the communication E5AN-HTPRR203BF-FLK INSTRUCTION Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.