Product model: E5AN-HTPRR203B-FLK
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON E5AN-HTPRR203B-FLK INSTRUCTION Manual.
Shell color: silver E5AN-HTPRR203B-FLK
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON E5AN-HTPRR203B-FLK INSTRUCTION Manual.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON E5AN-HTPRR203B-FLK INSTRUCTION Manual.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Appearance: T-shaped, slot center 10 mm.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: NPN output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements.
Two outputs: light-ON and dark-ON.
CComplete lineup including seven different shapes E5AN-HTPRR203B-FLK Manual.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations E5AN-HTPRR203B-FLK Manual.
Connector with lock that mates with commercially available,
connectors.