LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> GX-OD1628
OMRON GX-OD1628 Safety Precautions GX-OD1628 Manual
Product model: GX-OD1628
Name: EtherCAT Remote I/O Slaves
Brand: OMRON
Sort: Safety Precautions
File language: English
Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common GX-OD1628 Safety Precautions.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation GX-OD1628
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No GX-OD1628 Safety Precautions.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing GX-OD1628 Safety Precautions.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 20 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 200 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Classification: Equipped with operation indicator and diode to absorb coil surge.
Contact form: 4PST (standard).
Mounting method: Screw mounting .
Terminals: Connector.
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal Relay with 4 Independent.
Outputs.
Equipped with four G6B Mini-relays that are compact, highly sen,
sitive, and highly resistant to dielectric surges, and that can switch,
5 amps of power.
Sealed plastic construcction used for relays GX-OD1628 Manual.
Easy wiring with separated input/output terminals.
Special P6B Mounting Socket used to facilitate maintenance,
(except for high-reliability models).
UL and CSA certification for standard models,
(except for high-reliability models) GX-OD1628 Manual.
VDE certification for G6B-4BND/47BND/48BND for 12/24 VDC.
DIN Track mounting, and screw mounting models are available.