OMRON GX-OD1628 Rated current (ON current): 05 A/output, 40 A/common OMRON GX-OD1628
Brand: OMRON
Name: Digital I/O Terminal 3-tier Terminal Block Type
Model: GX-OD1628
Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.

Specifications: Outputs;
PNP (+ common); 32 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e OMRON GX-OD1628. g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H) GX-OD1628 Name: Clamp Terminal Blocks.
Specifications: Inputs; 8 inputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON GX-OD1628.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Classification: For output.
Internal I/O circuit common: NPN (– common).
I/O points: 8 output points OMRON GX-OD1628.
Connector Connection Models that.
Allows Easy Connection to Sensors and Output Devices.
Sensors with easy-to-wire connectors are easily,
attached or detached.
Connects to 2-wire sensors.
Remote teaching of the Sensor Terminal is possible.
with the PLC by using output signals of the Sensor Terminal.
DIN track mounting and screw mounting are available OMRON Digital I/O Terminal 3-tier Terminal Block Type. Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 outputs NPN OMRON Digital I/O Terminal 3-tier Terminal Block Type.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON Digital I/O Terminal 3-tier Terminal Block Type.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Expansion Units e-CON Connector type.
Specifications:Digital inputs and outputs;
4 inputs/ 4 outputs; PNP;
One Expansion Unit can be mounted to one,
CRT1-VAD02@@D or CRT1-VDA02@@D Analog I/O Slave Unit.
Standards: --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cosst can be reduced GX-OD1628.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee OMRON GX-OD1628.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.


...More relevant models >>>>
Last one: GX-OD1618
next one: GX-MD1618