The length of the line: 10M.
IP level: IP65.
Cable lead out direction: motor shaft different side.
Bending life: high bending life.
The cable is not shielded.
Encoder with cable (motor side); for HF-KP/HF-MP series (motor shaft with side extraction). MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series MITSUBISHI MR-J2S-20CP INSTRUCTION MANUAL.
Rated output: 1.0kw.
Interface type: CC-Link communication type (built-in positioning function)
MR-J2S-20CP
Power specification: three phase AC200V.
Positioning operation by setting position and rotational speed data in the positioning table and receiving the start signal from the main controller.
The setting of the position and speed of the positioning table, as well as the start and stop operation can be completed through CC-Link communication MITSUBISHI MR-J2S-20CP INSTRUCTION MANUAL.
By using the MR-J3-D01 extension IO unit, the DI/O instruction can be used to select and locate the table.
(CC-Link can not be used for MR-J3-D01 communications).
With built-in positioning function of the servo amplifier, can be set through the CC-Link communications and speed data. (corresponding to the CC-Link version: Ver.1.10)
Can be achieved through the CC-Link communications to start, stop and monitoring and other operations MITSUBISHI MR-J2S-20CP INSTRUCTION MANUAL.
Serial communication reduce wiring.
Distributed servo control system can be built by CC-Link communication.
The parameters of unit MR-PRU03 (optional) the parameter setting, operation and monitoring more convenient.
The servo amplifier can be used for speed control operation.
When the two stations are occupied, the speed can be set directly by the remote register. Cable length: 5m.
For MR-J2S-700A (4) /CP/CL or less.
Encoder for HC-SFS; HC-LFS; HC-RFS; 2000r/min HA-LFS; HC-UFS servo motor.
-H products have a long flex life.
Coding is not resistant to oil. Drive unit.
MITSUBISHI universal AC servo amplifier MELSERVO-J4 series.
Rated output: 37kw.
Interface: SSCNET III /H.
Power supply: three phase AC400V.
Special specifications: full closed control 4 wire / support mechanical end encoder ABZ phase input / support positioning mode.
Support position control, speed control, torque control.
Position control to follow the position instructions.
When thhe control is inserted, the position control is performed MR-J2S-20CP Manual.
Speed control follows the speed command to control the speed within a certain range.
Torque control to follow the torque command to control the stable torque.
Function of switching amplitude MR-J2S-20CP Manual. The increase in the process of switching and stopping,
And in the operation of the use of the switching signal, switching growth.