LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q04UDVCPU
MITSUBISHI Q04UDVCPU Manual Q04UDVCPU Common Instructions Programming Manual
Product model: Q04UDVCPU
Name: PLC
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
Control axis: maximum 32 axes.
Compact size and space saving.
Using the same hardware structure and MELSEC-Q series PLC, to achieve the same product installation area, the size of the industry.
Using 12 slot substrate, more space and cost savings.
Can share PLC MELSEC-Q power module, substrate, and I/O module Q04UDVCPU Programming Manual.
The control process can be assigned to each CPU module in the multi CPU system, which is equivalent to the intelligent control system Q04UDVCPU
In PC (Computer Personal) CPU.Master / local station sharing.
IE CC-Link field network.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs Q04UDVCPU Programming Manual.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX Q04UDVCPU Programming Manual.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
QJ71GF11-T2 can be used as the main station / local station of IE CC-Link field network.8 channels.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100).
Shedding detection function.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent thee loss of the program and the parameters due to forgetting to replace the battery Q04UDVCPU Manual .
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and otther planned downtime,
The data is lost due to battery depletion Q04UDVCPU Manual .
The next time the power is turned on, the backup data will be automatically restored.
Related products
MITSUBISHI
General high speed CPU
Q04UDVCPU
MITSUBISHI General high speed CPU Q04UDVCPU
Input / output points: 4096 points. Inpu
MITSUBISHI
General high speed CPU
Q26UDVCPU
MITSUBISHI General high speed CPU Q26UDVCPU
Input / output points: 4096 points. Inpu
MITSUBISHI
General purpose CPU
Q04UDHCPU
MITSUBISHI General purpose CPU Q04UDHCPU
Input / output points: 4096 points. Num
MITSUBISHI
General high speed CPU
Q06UDVCPU
MITSUBISHI General high speed CPU Q06UDVCPU
Input / output points: 4096 points. Inpu