LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q00JCPU-S8-SET
MITSUBISHI Q00JCPU-S8-SET Programming Manual PLC Special Instructions Manual
Product model: Q00JCPU-S8-SET
Name: PLC
Brand: MITSUBISHI
Sort: Special Instructions Programming Manual
File language: English
12 slots.
The main substrate needs to be equipped with CPU and power supply.
Support for high speed communication between multi CPU.
Requires 1 power modules.
Used to install Q series modules.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q00JCPU-S8-SET Manual Q00JCPU-S8-SET
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control Q00JCPU-S8-SET Manual . For 16 point I/O. 0.3 to 1.5mm2 (AWG22 to 16).Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 40 K step.
Processing speed: 0.0095 s.
Program memory capacity: 160 KB.
Support USB and RS232.
Support installed memory card.
Providing high speed communication between multiple CPU.
High speed and high precision data processing Q00JCPU-S8-SET Manual .
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0.014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing MITSUBISHI PLC Manual .
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula MITSUBISHI PLC Manual .
Shorten the fixed scan interrupt time, high precision device.
The minimum interval of the fixed period interrupt program is reduced to 100 s.
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device MITSUBISHI PLC Manual . Output points: 8 points.
Output voltage and current: DC5~24A/ point; 8A/ common terminal.
OFF leakage current: 0.1mA.
Response time: 10ms.
Leaky type and source sharing.
18 point terminal station.
With the surge absorber.
All points of independence.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data traansceiver time between the CPU module Q00JCPU-S8-SET Programming Manual.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily diisplayed Q00JCPU-S8-SET Manual .
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Related products
MITSUBISHI
Small points with substrate CPU
Q00JCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-S8-SET
Input / output points: 256 points. Progr
MITSUBISHI
CPU with base plate
Q00JCPU
MITSUBISHI CPU with base plate Q00JCPU
Program capacity: 8K step. Input / outpu
MITSUBISHI
Small points with substrate CPU
Q00JCPU-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-SET
Input / output points: 256 points. Progr
MITSUBISHI
Small points with substrate CPU
Q00UJCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00UJCPU-S8-SET
Upgrade payments. Input / output points: