Cable length: 1.0m.
Weight: 0.23kg.
Definition 1: conductor by one or a plurality of mutually insulated and insulating protective layer made of,
A conductor of electricity or information from one place to another.
Definition 2: usually by a few or several groups (each with at least two wires) cable rope twisted the similar,
Each group of wires are insulated from each other, and are often twisted around a center,
The entire outer bread has a highly insulated cover L26CPU-PBT User's Manual
L26CPU-PBT
The cable has the characteristics of internal power and external insulation. IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function L26CPU-PBT User's Manual.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
Management of abnormal information through the RAS function
An error occurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network L26CPU-PBT User's Manual.
Even if the power of the system is cut off, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime. Open collector output.
Axis of control: 4.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the limitatiion of the concept of the electronic cam control so far, and can use the cam with high degree of freedom L26CPU-PBT Manual.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same timee L26CPU-PBT Manual.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format.