DB A20 AnyWire master station.
Transmission distance: the longest 3km.
Data input and output: up to 1024 points.
Connect up to 128 units.
Enter 512 points, 512 points out of the output.
Support environmental protection, high speed, long distance transmission and special distribution system to support the special flat cable, universal VCTF cable, universal single wire cable and other cable L02SCPU-P Programming Manual
L02SCPU-P
Using original transmission mode, there is almost no branch limit,
Supports the automatic track and ring transmission,
Can also create suitable for small and medium sized factory wiring system.
Support remote I/O, analog quantity, temperature and humidity terminal, anti false operation terminal and other equipment L02SCPU-P Programming Manual.
Up to 128 units from the station module
Can connect up to 128 units from the station module, for up to 1024 points (input 512 points / output 512 points) of the I/O control.
In addition, the parameters can be set through the switch, easy to set the transmission distance of 50m/200m/1km/3km. Transmission speed: 100Mbps/10Mbps.
MELSOFT connection.
SLMP cross letter (MC protocol).
Communication protocol support function L02SCPU-P Programming Manual.
E-mail function.
Web function.
Collect / change CPU module data from the other side of the device.
SLMP (MC protocol) communication
SLMP is a protocol that uses Ethernet to access SLMP devices from the other device.
If it is possible to follow the SLMP control procedures to send and receive messages to the device,
The communication can be carried out by SLMP. MC can also support the previous agreement.
MELSOFT connection
Can be connected with the programming tool Works2 GX and other MELSOFT products.
In addition, through the use of communication tools to support the sale of (MX Component),
Regardless of the details of the protocol (how to send and receive procedures),
Can create a communication program on the upper side of the system.
It can easily connect to BACnet and MODBUS /TCP
Communication protocol support function
Through the Works2 GX communication protocol support function, can easily set the communication with the other equipment required for the agreement. Open collector output.
Axis of control: 4.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the llimitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom L02SCPU-P Manual.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same timee L02SCPU-P Manual.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format.