"IE Field CC-Link master / local station
Transmission speed: 1Gbps.
Remote input / output: 16384 points.
Remote register: 8192 words.
Can be applied to the serial number of the top 5 for the "13012" and after the CPU module.
Simply set the parameters, you can easily start the network.
Simply use the Works2 GX, set the network parameters in the 1 master station, you can easily connect all the slave stations L02SCPU-P Reference Manual
L02SCPU-P
Also, when you need to change the system, you only need to change the parameters.
High degree of freedom network
Build star, linear, star and linear mixed model, and ring network,
Therefore, can freely set the scene equipment.
When you use HUB, you just need to connect the cable to the free port to build the network easily,
Additional equipment and re layout of the corresponding is also more simple L02SCPU-P Reference Manual. "Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector L02SCPU-P Reference Manual.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Output points: 16 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called L02SCPU-P Manual.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch L02SCPU-P Manual.
Communication protocol is a standard Modbus protocol or custom protocol.