MITSUBISHI FX3U-64CCL Manual FX3U-64CCL USER'S MANUAL
Product model: FX3U-64CCL
Name: Module
Brand: MITSUBISHI
Sort: USER'S MANUAL
File language: English
Used to reduce radio noise.Power: 30kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. "MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V FX3U-64CCL USER'S MANUAL.
Frequency converter capacity: 11KW.
The use of frequency converter motor is in order to speed, and reduce the starting current FX3U-64CCL
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter) FX3U-64CCL USER'S MANUAL.
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter. "MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 18.5kw.
SLD converter rated current: 93A.
Structure and function: Standard model FX3U-64CCL USER'S MANUAL.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Power: 37kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FX3U-64CCL Manual.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space annd reduce the comprehensive cost FX3U-64CCL Manual.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving.
Related products
MITSUBISHI
PLC
FX3U-16MT/DSS
MITSUBISHI PLC FX3U-16MT/DSS
Max input / output points: 16 points. Po
MITSUBISHI
PLC
FX3U-64MT/ES-A
MITSUBISHI PLC FX3U-64MT/ES-A
Max input / output points: 64 points. Su
MITSUBISHI
PLC
FX3U-48MR/DS
MITSUBISHI PLC FX3U-48MR/DS
Max input / output points: 48 points. Po